The Length Gauge (Elongation Index BS), is used to measure the elongation index of aggregates. When the length of the particle is more than 1.8 of the midsize of the sieve fraction, it is considered elongated. The aggregate to be classified is separated into six sieve fractions from 6.3 to 50 mm and each fraction is examined separately.