{{ variable.name }}
Overview
I. Product Functions:
The SXML-107 Reinforcement Concrete Slab Comprehensive Tester combines the functions of a reinforcement scanning instrument and a slab thickness tester. It is used to detect the position, cover thickness, spacing, and diameter of reinforcement bars within concrete structures, as well as to measure the thickness of non-magnetic components such as cast-in-place slabs, walls, beams, columns, and wood. When using this instrument to test slab thickness, it can first identify the distribution of reinforcement bars, select the optimal testing location, avoid the influence of reinforcement bars within the slab on the results, and achieve more accurate testing outcomes.
II. Technical Features:
1. When using this instrument to test slab thickness, it can first identify the distribution of reinforcement bars, select the optimal testing location, avoid the influence of reinforcement bars within the slab on the results, and achieve more accurate testing outcomes.
2. Utilizes a new ARM high-speed acquisition system, providing fast instrument response, full-color LCD display, real-time simultaneous display of cover thickness and spacing data, quick positioning of reinforcement bars, significantly improving detection speed and accuracy.
3. Can be calibrated according to on-site conditions, further enhancing the authenticity and reliability of detection data.
4. Silicone dust-proof keys for more comfortable field operation.
5. Brightness adjustment, allowing selection of backlight brightness levels based on external lighting conditions, with eight adjustable settings.
6. Theme selection to improve screen visibility under outdoor lighting conditions.
Ⅲ. Technical Indicators:
1. During thickness testing and grid testing, both the rebar cover thickness and rebar distribution spacing can be displayed simultaneously.
2. Automatically displays rebar spacing, with an error range of ±1 mm, and can display the rebar grid distribution diagram.
3. Rebar cover thickness measurement (nominal) range:
First range (nominal): 6 mm to 90 mm;
Second range (nominal): 7 mm to 200 mm;
4. Rebar cover thickness calibration range: 0 to ±50 mm;
5. Rebar diameter measurement (nominal) range: Ф6 to Ф50 mm;
6. Maximum allowable error for rebar cover thickness measurement:
Maximum allowable error (mm) | Rebar cover thickness
First range (nominal) (mm) | Rebar cover thickness
Second range (nominal) (mm)
≤±1 | 6 to 59 | 7 to 79
≤±2 | 60 to 69 | 80 to 119
≤±4 | 70 to 90 | 120 to 200
7. Rebar diameter measurement value error range: ±1 grade;
Floor slab thickness measurement:
1. Smartly identifies and automatically locks the minimum value, displaying the thickness value digitally without manual comparison.
2. Signal bar indication function, which can display based on signal strength to easily locate the alignment points of upper and lower probes.
3. Thickness measurement range: 40 mm to 999 mm
4. Measurement accuracy: 40 mm to 600 mm ±1 mm; 601 mm to 999 mm ±2 mm
Superior measurement accuracy compared to similar products
5. Thickness calibration range: 0 to ±50 mm
6. Display: Color screen, 8-level brightness adjustment, three theme options, suitable for different outdoor lighting angles
7. Data storage capacity: Can store over 200,000 thickness measurement points
8. Data transmission method: Type-C data interface
9. Professional data analysis software for PC, making data processing and report generation effortless
10. Working environment requirements:
Environmental temperature: -10°C to +50°C, avoid prolonged direct sunlight exposure
Relative humidity: ≤ 90% RH
Electromagnetic interference: No strong alternating electromagnetic field
11. Power supply: Built-in rechargeable lithium battery, providing up to 50 hours of operation
12. Main unit dimensions: 219 mm × 56 mm × 139 mm
Ⅳ.Instrument Composition:
Includes:
Main unit,
rebar detector,
scanning cart,
floor slab transmitting probe,
floor slab receiving probe,
walkie-talkie,
probe connection cables,