Overview

.Product Features:

Measure the corrosion probability of rebars within concrete walls, beams, and columns.

 

.Technical Characteristics:

1. Permanent fixed metal electrodes, eliminating the need for copper sulfate solution injection and replacement, thus avoiding harm to operators and the environment;

2. Measures using both potential method and gradient method, equipped with potential and gradient electrodes;

3. Utilizes a new ARM high-speed acquisition system, significantly enhancing detection speed and accuracy;

4. Full-color LCD screen with silicone dust-proof keys, providing a more comfortable on-site operation experience;

5. Brightness adjustment, allowing selection of backlight brightness levels based on external lighting conditions, with eight adjustable settings;

6. Theme selection to improve screen visibility under outdoor lighting conditions.

 

.Main Technical Specifications:

1. Measurement Potential: ±1000mV;

2. Testing Accuracy: ±1mV;

3. Measuring Point Spacing: 1-100cm;

4. Data Storage Capacity: 5400 measurement zones, 228000 data points;

5. Measurement Area: 8100 square meters;

6. Operating Environment Requirements: Temperature range -10°C to +50°C, avoid prolonged direct sunlight exposure, relative humidity ≤ 90% RH, no strong alternating electromagnetic fields;

7. Power Supply: Built-in rechargeable lithium battery, providing up to 50 hours of operation;

8. LCD Display Resolution: 480×800 pixels;

9. Main Unit Dimensions: 219mm×56mm×139mm.

 

.Instrument Composition: 

Main unit, two sensors, two connecting cables, bracket, transmission line, software CD, etc.