Menu

SXZT707

{{ product.price_format }}
{{ product.origin_price_format }}
Quantity:
Brand: ZHKEYQ
SKU:{{ product.sku }}
Model: {{ product.model }}

{{ variable.name }}

{{ value.name }}

Product features:
1. Measure the thickness of concrete cover
2. Locate the position of rebar
3. Estimate the diameter of rebar
4. Test rebar spacing and display rebar grid distribution
5. Detect ferromagnetic and conductive materials in non-magnetic and non-conductive media

Based on standard specifications:
GB 50010-2010 'Code for Design of Concrete Structures' (2015 edition)
GB 50204-2015 'Code for Acceptance of Construction Quality of Concrete Structures'
GB/T 50344-2019 'Standard for Testing Techniques of Building Structures'
JGJ/T 152-2019 'Code for Testing Techniques of Reinforcement in Concrete'
DB11/T 365-2016 'Code for Testing Thickness of Concrete Cover and Diameter of Reinforcement by Electromagnetic Induction Method'
GBT/ 50784-2013 'Standard for On-site Testing Techniques of Concrete Structures'

Technical features:
1. Simultaneous display of concrete cover thickness, rebar position, and rebar spacing; automatic center determination of rebar position
2. Two-dimensional laser positioning, real-time display of rebar position and adjacent rebar centerline
3. Multiple reminders through display frame and indicator light signals, facilitating rebar location and core drilling
4. Optimized algorithm for dense rebar patterns, effectively reducing the interference of stirrups
5. Dense waveform detection, significantly improving the accuracy of rebar count and concrete cover thickness
6. Reverse compensation, automatically calculating and adjusting for complex site conditions to correct concrete cover data deviations

 

Main technical specifications:

1. Rebar diameter setting range: φ6mm~φ50mm

2. Measuring range for different rebar diameters

Range/Diameter (mm) Small Range (mm) Large Range (mm)

φ6~Φ8 1~60 5~120

φ10~Φ20 1~80 5~160

φ22 and above 1~120 5~210

3. Error range for different thicknesses

Range/Error Range (mm) Small Range (mm) Large Range (mm)

±1 1~80 5~80

±2 81~120 81~120

±4 - 121~210

4. Diameter estimation applicable range: φ6mm~φ50mm

5. Maximum diameter estimation error (specification): ±1 specification

6. Distance accuracy: ±1mm

7. Scanning modes: Standard scan, procedure scan, grid scan, profile scan, fine scan, image scan

8. Power supply: Built-in high-capacity lithium battery

9. Operating language: Chinese-English switch

10. Backlight brightness: 8 levels adjustable

11. Theme settings: 5 theme choices

12. Operating temperature: -10℃~+50℃

13. Main unit dimensions: 219mm×92mm×106mm

 

14. Weight: 0.6kg

 

Instrument composition: includes: main unit, charger, software CD, packaging box, etc.