{{ variable.name }}
SXSZ-R51S (black and white version)
Features:
Large-capacity SD card storage
Equipped with rebar correction function, ensuring more accurate measurement of rebar cover thickness in structures with ties
Adopts ARM high-speed acquisition system for faster testing
Technical specifications:
Rebar diameter range: Ф6mm~Ф50mm
Cover thickness range: First range: 6mm~90mm; Second range: 7mm~190mm
Maximum allowable error for cover thickness:
First range: ±1mm for 2~60mm, ±2mm for 60~70mm, ±3mm for 80~90mm, ±4mm for 90~100mm, ±5mm for 120~160mm, ±6mm for 160~190mm
Second range: ±1mm for 2~60mm, ±2mm for 60~80mm, ±3mm for 80~90mm, ±4mm for 90~120mm, ±5mm for 120~160mm, ±6mm for 160~190mm
Diameter measurement range: Ф6mm~Ф50mm
Maximum allowable error for diameter measurement: ±1 grade
Operating environment requirements: Ambient temperature: -10℃~+40℃; Relative humidity: <90%RH; Electromagnetic interference: No strong alternating electromagnetic field; Avoid prolonged direct sunlight
Standards used:
Technical Code for Detection of Reinforcement in Concrete JGJ/T152-2019
Code for Acceptance of Construction Quality of Concrete Structure Engineering GB 50204-2015
Standard for Testing Technology of Building Structures GB/T50344-2004
Code for Design of Concrete Structures (2015 Edition) GB50010-2010
Technical Code for Detection of Concrete Cover Thickness and Diameter of Reinforcement by Electromagnetic Induction DB11/T365-2016
Standard for On-site Testing Technology of Concrete Structures GBT/50784-2013
Calibration Specification for Concrete Cover Thickness Tester and Floor Thickness Tester JJF1224-2009