The SZ-R51T+/SZ-R51T rebar locator is used to detect the diameter, position, distribution, and concrete cover thickness of rebars within existing or newly constructed reinforced concrete.
Features: Based on SXR51, it has been enhanced with:
1. A color LCD screen, dust and water-resistant silicone buttons, and a more compact design for easy portability.
2. Removable original Panasonic lithium battery. The lithium battery can be removed for charging or charged directly using a power bank, making it convenient for on-site use;
Technical Specifications
Rebar diameter range: Ф6mm to Ф50mm
Cover thickness range: First range: 6mm to 90mm; Second range: 7mm to 180mm
Maximum allowable error for cover thickness:
First range: ±1 for 6 to 59mm; ±2 for 60 to 69mm; ±4 for 70 to 90mm
Second range: ±1 for 7 to 79mm; ±2 for 80 to 119mm; ±4 for 120 to 180mm
Diameter measurement range: Ф6mm to Ф50mm
Maximum allowable error for diameter measurement: ±1 grade
Scanning boundary: No boundary
Operating environment requirements: Temperature: -10℃ to +40℃; Relative humidity: <90%RH; Electromagnetic interference: No strong alternating electromagnetic field; Direct sunlight exposure should not be prolonged
Power supply: 6 AA alkaline batteries, with a usage time exceeding 30 hours
According to the standards:
Reinforcement Detection Technology Code for Concrete JGJ/T152-2019
Code for Quality Acceptance of Construction of Concrete Structure Engineering GB 50204-2015
Standard for Testing Technology of Building Structures GB/T50344-2004
Code for Design of Concrete Structures (2015 Edition) GB50010-2010
Technical Code for Detection of Reinforcement Cover Thickness and Diameter by Electromagnetic Induction DB11/T365-2016
Standard for On-site Testing Technology of Concrete Structures GBT/50784-2013
Calibration Specification for Reinforcement Cover Thickness Tester and Floor Thickness Tester JJF1224-2009